Polymeric Metal Oxide Gapless Lightning Arrester For Electrical Substation 11kV

China Polymeric Metal Oxide Gapless Lightning Arrester For Electrical Substation 11kV supplier
Polymeric Metal Oxide Gapless Lightning Arrester For Electrical Substation 11kV supplier Polymeric Metal Oxide Gapless Lightning Arrester For Electrical Substation 11kV supplier

Large Image :  Polymeric Metal Oxide Gapless Lightning Arrester For Electrical Substation 11kV

Product Details:

Place of Origin: WENZHOU
Brand Name: QIUPU
Certification: IEC
Model Number: HY5W-11/36

Payment & Shipping Terms:

Minimum Order Quantity: 51 PCS
Packaging Details: CARTONS
Delivery Time: 7 Days
Payment Terms: T/T, Western Union
Supply Ability: 500000PCS/MONTH
Contact Now
Detailed Product Description
Rate Voltage: 11kV Frequency Voltage: 42V
Rate Current: 150A-250A Shock Voltage: 110-170 BIL
2 Ms Current: 150A Short Current: 100 KA

    HY5W-11/36 Zinc Oxide Arrester with Electrical Switchgear Euipment

 

 

Specification:

     

Rated Voltage Work Voltage AC Current
11KV 36kV 10A
     

   

 

    At the same time, this value should be compared with the manufacturer's specified value, the change should not be greater than 5 %. If the MOA is too low, it may explode under the transient overvoltage of various operations and faults. If the surface of the MOA ceramic cover is seriously damped, the measurement value will also be affected, so the surface leakage should be eliminated during the test. Measurement of alternating current leakage of operating voltage. The test is to measure the total current, resistance current and power loss.

 

If the total current value is measured to be more than 20 % higher than the initial value, or to exceed the manufacturer's specified value, it should cause immediate concern and strengthen the operation monitoring. If the total current value is measured to be more than 50 % higher than the initial value, the operation should be eliminated.

 

If the measured resistance current more than double the factory's specified value, should also be out of operation, until the reason for removal or replacement, but can not take the fault operation. In conducting the above-mentioned tests on MOA, the current ambient temperature, relative humidity and operating voltage should be recorded, and the effects of the related interference should be noted and eliminated in the tests.