Casting Resin Indoor High Voltage Current Transformer Single Phase / 3 Phase

Place of Origin WENZHOU
Brand Name QIUPU
Certification IEC/GB1208
Model Number LZZBJ9-35
Minimum Order Quantity 50PCS
Packaging Details Cartons/Woodens
Delivery Time 7 Days
Payment Terms T/T, Western Union
Supply Ability 50000PCS/Months

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Material Casting Resin Insulation Level 40.5/95/200kV
Rated Power 50Hz/60Hz Temperature -5degree - 40 Degree
Accuracy Class 0.2/0.2 Rated Secondary Current 5A/1A
Color Brown Short-time Thermal Current 150I 1 N
High Light

high voltage current transformer

,

zero sequence current transformer

Leave a Message
Product Description

LZZBJ9-35 Casting Resin Indoor High Voltage Current Transformer

 

 

The primary coil is in series in the circuit, and the number of turns is very small. Therefore, the current in the primary coil depends entirely on the load current of the circuit being tested, but not on the secondary current;
The current coil impedance of the current Transformer secondary coil and the relay are very small, so under normal circumstances, the current Transformer is running near short circuit.
The ratio of the first and second rated current to the current Transformer, called the rated mutual inductance ratio: kn = I1n / I2n
Since primary coil rated current I1n has been standardized and secondary coil rated current I2n has been unified to 5(1 or 0.5) Ann, the rated mutual inductance ratio of current Transformer has also been standardized. Kn can also be expressed roughly as the turn ratio of the first and secondary coils of the transformer, i.e. the turn ratio of N1. N2 to the first and second coils in the Kn _ kN = N1/N2.

There are two kinds of transformer, voltage Transformer and current Transformer. Voltage transformer can be used for measuring voltage and power in high-voltage and high-voltage power systems. The current Transformer can be used for the measurement of exchange current, the measurement of exchange voltage and the protection of power drag lines.
Voltage transformer


By purpose


Measurement winding of voltage Transformer or voltage transformer for measuring: To provide grid voltage information to measuring device within normal voltage range;
Protection winding of voltage Transformer or voltage transformer for protection: In the state of power grid failure, provide information on power grid failure voltage to relay protection devices.

 

 

Ratedprimary Current Accuracy class Insulation Level
20-2500A 0.2/0.2 40.5/95/200kV