StephanQiuPu is a great electric power factory. we satisfy you very much . will cooperate with you again!
Drive Type Indoor Vacuum High Voltage Load Switch For Industrial Power Euipments
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xRate Voltage | 12kV | Frequency Voltage | 42kV |
---|---|---|---|
Stable Current | 31.5kA/4s | Current | 400A-630A |
Life | 1000 Times | Light Frequency Voltage | 75kV |
High Light | hv disconnect switch,load break disconnect switch |
FN7-12 High Voltage Indoor Vacuum Load switch with switcgear
1. The type FN7-12RD high voltage indoor vacuum load switch and electrical comination is use for Three phase alternating current Concurrent 50HZ industrial power euipments , its can laod control and protect short current . Load switch is open-close load , closed current , and charging cables current . Electrical comination can close any current . There can be use by hand and power .
2. FN7-12RD is designed by drive type , light weight .
3. The full name of the air switch is the air type low-voltage circuit breaker which belongs to the circuit breaker.
It's called an air low-voltage circuit breaker or air switch because it's done by using air as a medium.
The isolation switch is a kind of high voltage switch electrical appliance mainly used in high voltage circuit .
4. A switching device capable of breaking and carrying current under normal loop conditions and of carrying and breaking current under abnormal loop conditions within a specified time.
It has the function of overload, short circuit and undervoltage protection, and has the ability to protect the line and power supply.
Item | Technical data | ||||||||||||
Rated voltage (KV) | 12 | ||||||||||||
Rated frequency(Hz) | 50 | ||||||||||||
Insulator(capacity) | insulating | Frequency withstand voltage 5 min (KV) | 42 | ||||||||||
Frequency withstand voltage 1 min (V) | 2000 | ||||||||||||
Lighting impulse withstand voltage (KV) | 75 | ||||||||||||
Short Current | 31.5kA | ||||||||||||
Altitude | 8 | ||||||||||||