Epoxy Resin Insulator
-
Medium Voltage Insulators
-
High Voltage Epoxy Resin Insulator
-
Vacuum Circuit Breaker
-
Epoxy Resin Bushing
-
Electrical Switchgear Components
-
Cast Resin Transformer
-
Earthing Switch
-
Copper Electrical Contacts
-
High Voltage Disconnect Switch
-
Zinc Oxide Lightning Arrester
-
Industrial Cable Ties
-
Electrical Conduit Plastic Pipe
-
High Voltage Indicators
-
Moulded Case Circuit Breaker
-
Load Breaker Switch
-
StephanQiuPu is a great electric power factory. we satisfy you very much . will cooperate with you again!
4 Poles Mccb Low Voltage Moulded Circuit Breaker Switch
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xName | Mccb Switch | Rated Voltage | 400V (380V) |
---|---|---|---|
Rated Current | 200A-1000A | Short Circuit Splitting Capacity | 30kA~42kA |
Poles | 3/4 Poles | Feature | Full Intelligence, High Segmentation |
High Light | electronic trip circuit breaker,60 amp circuit breaker |
4 Poles Mccb Low Voltage Moulded Circuit Breaker Switch
Introduction
HKW1-1000 intelligent universal circuit breaker (hereinafter referred to as circuit breaker), suitable for AC 50Hz, rated voltage 400V
(380V), in a distribution network with a rated current of 200~1000A, it is mainly used to distribute electrical energy and protect circuits and power equipment from
Damaged by overload, short circuit, under voltage, single-phase grounding and other faults. Under normal conditions, it can be used for infrequent conversion of lines,
The page can be used for infrequent starting and protection of the motor.
The circuit breaker has a variety of intelligent protection functions, selective protection is accurate, can improve the reliability of power supply, avoid unnecessary
9
Blackout. The circuit breaker has isolation function, the symbol is marked as
The technical performance of the circuit breaker conforms to GB14048.2 "Low-voltage switchgear and control equipment Part 2: Circuit breaker"
IEC60947-2 "Low-voltage switchgear and control equipment Part 2: Circuit breaker" and other standards.
Feature
O has the characteristics of full intelligence, high segmentation, zero arc flash, etc.;
O AC rated current 200A-1000A, short circuit capacity 30kA~42kA;
O has 3 poles and 4 poles, drawer type and fixed type, can be installed into the line;
O has a variety of intelligent controllers, providing different functions: intelligent function, display function.
O setting function, monitoring function, fault memory function, can bring communication interface to achieve telemetry, remote adjustment, remote control, remote communication;
O protection features are complete, easy to set, high precision, with instantaneous, short delay, long delay, single-phase grounding and other protection features.
classification
◎According to the use category: A type (non-selected type);
Type B (selected type)
◎ Installation method: fixed type, drawer type;
◎ Transmission mode: motor drive, manual;
◎Number of poles: three poles, four levels;
◎Release type: intelligent controller, shunt release, undervoltage instant (or delay) release;
◎Classification of intelligent controller:
2M type: economic type (basic function)
3M type: basic type (basic function + intelligent function)
3H type: advanced type (basic function + intelligent function + communication interface)
Normal working conditions and installation conditions
◎Ambient air temperature: The upper limit does not exceed +40C; the lower limit does not exceed -5C; the average value of 24h does not exceed +35*C;
Note: 1. The lower limit is a working condition of 10C or -25°C, the user must declare to the manufacturer when ordering;
2. For working conditions where the upper limit value exceeds +40°C or the lower limit value is below -25°C, the user should consult with the manufacturer.
◎ Altitude: The altitude of the installation site does not exceed 2000m.
◎Atmospheric conditions: the relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40°C, and it can be higher at lower temperatures
Relative humidity, the average maximum relative humidity of the wettest month is 90%, and the average monthly minimum temperature of the month is +25°C,
And take into account the doubts that occur on the surface of the product due to temperature changes.
◎Pollution level: Level 3
◎Installation category: The installation category of the main circuit of the circuit breaker is category IV, and the installation category of the auxiliary circuit except the undervoltage release coil,
The primary coil of the power transformer is the same as the main circuit of the circuit breaker, and the rest are 1 class.
◎Category of use: Class B
◎Installation conditions: The circuit breaker should be installed according to the installation requirements of the instruction manual. The vertical inclination of the circuit breaker does not exceed 5%.