Epoxy Resin Insulator
-
Medium Voltage Insulators
-
High Voltage Epoxy Resin Insulator
-
Vacuum Circuit Breaker
-
Epoxy Resin Bushing
-
Electrical Switchgear Components
-
Cast Resin Transformer
-
Earthing Switch
-
Copper Electrical Contacts
-
High Voltage Disconnect Switch
-
Zinc Oxide Lightning Arrester
-
Industrial Cable Ties
-
Electrical Conduit Plastic Pipe
-
High Voltage Indicators
-
Moulded Case Circuit Breaker
-
Load Breaker Switch
-
Power Distribution Transformer
-
StephanQiuPu is a great electric power factory. we satisfy you very much . will cooperate with you again!
FN5-12 High Voltage Indoor Vacuum Load Switch GB3804 IEC420 Standard

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xRate Voltage | 12kV | Frequency Voltage | 42kV |
---|---|---|---|
Stable Current | 31.5kA-50kA/4s | Current | 50A-125A |
Light Frequency Voltage | 75kV | Wide | 550mm |
Highlight | hv disconnect switch,load break disconnect switch |
FN7-12 High Voltage Indoor Vacuum Load switch with switcgear
Features:
1. The type FN5-12R(L) high voltage indoor vacuum load switch and electrical comination is use for Three phase alternating current Concurrent 50HZ industrial power euipments , its can load control and protect short current . Load switch is open-close load , closed current , and charging cables current . Electrical comination can close any current . There can be use by hand and power .
2. FN5-12R(L) is designed by drive type , light weight .
3. FN5-12R(L) is standard by GB3804 and IEC420 .
4. The full name of the air switch is the air type low-voltage circuit breaker which belongs to the circuit breaker.
It's called an air low-voltage circuit breaker or air switch because it's done by using air as a medium.
The isolation switch is a kind of high voltage switch electrical appliance mainly used in high voltage circuit .
5. A load switch is an electrical switch between an isolation switch and a circuit breaker. It has a simple arc extinguishing device that can cut the rated load current and a certain overload current, but can not cut the short circuit current.
Item | Technical data | ||||||||||||
Rated voltage (KV) | 12 | ||||||||||||
Rated frequency(Hz) | 50 | ||||||||||||
Insulator(capacity) | insulating | Frequency withstand voltage 5 min (KV) | 42 | ||||||||||
Frequency withstand voltage 1 min (V) | 2000 | ||||||||||||
Lighting impulse withstand voltage (KV) | 75 | ||||||||||||
Short Current | 31.5kA-50kA | ||||||||||||
Altitude | 1000 | ||||||||||||