40.5KV outdoor Vacuum Type Circuit Breaker With Voltage transformer
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Details
Place Of Origin | Zhejiang, China | Type | High Voltage |
---|---|---|---|
Rated Voltage | 40.5KV | Rated Frequency | 50Hz |
Rated Breaking Current | 630A-4000A | ||
High Light | VCB Vacuum Type Circuit Breaker,12KV Vacuum Type Circuit Breaker,Isolation Vacuum Type Circuit Breaker |
Product Description
40.5KV outdoor Vacuum Type Circuit Breaker With Voltage transformer
Specification
Packing & Delivery
1. Standard export wooden case 2. Customized
Environmental Conditions
1. Ambient temperature: -15℃- 40℃ 2.Ambient humidity Daily mean relative humidity: ≤95% Monthly mean relative humidity: ≤90%
Daily mean vapor pressure: ≤2.2×10-3 MPa Monthly mean vapor pressure: ≤1.8×10-3 MPa
3. Altitude: not exceed 2000m; 4.Polar distance 150mm, altitude ≤1000m; 5.Please contact us for special operating conditions.
Note:(1). When test is carried out at altitude of less 1000m, 42should be adjust to 48, 75 to 85(expect for polar distance 150mm).
(2). When the rated current is 4000A, switchgear should be equipped with force air cooling system.
(3). Rated parameter provides when need.
(4). Welcome contact us to confirm latest parameter.
Daily mean vapor pressure: ≤2.2×10-3 MPa Monthly mean vapor pressure: ≤1.8×10-3 MPa
3. Altitude: not exceed 2000m; 4.Polar distance 150mm, altitude ≤1000m; 5.Please contact us for special operating conditions.
Note:(1). When test is carried out at altitude of less 1000m, 42should be adjust to 48, 75 to 85(expect for polar distance 150mm).
(2). When the rated current is 4000A, switchgear should be equipped with force air cooling system.
(3). Rated parameter provides when need.
(4). Welcome contact us to confirm latest parameter.