Hot sale IP2X XGN2-12 AC Box-type fixed metal-enclosed switchgear
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
x| Model Number | XGN2-12 | Rated Voltage | 3.6/7.2/12KV |
|---|---|---|---|
| Rated Frequency | 50Hz | Air Temperature | -15℃~+40℃ |
| Rated Currentncy | 630A-3150A | Protection Level | IP2X |
| Highlight | IP2X switchgear,Hot sale switchgear |
||
XGN2-12 AC Box-type fixed metal-enclosed switchgear
Product description
XGN2-12 box-type fixed metal-enclosed switchgear (switch cabinet for short) is used in 3.6, 7.2, 12KV three-phase AC 50Hz systems to receive and distribute electrical energy. It is suitable for frequent operations. Its bus system is a single bus. (Single bus with bypass and double bus structure can be derived). This switchgear meets the requirements of the national standard GB3906-91 "3~35KV AC metal enclosed switch equipment" and the national standard IEC298, and has two proposed "five-proof" locking functions.
The main switch of this switchgear adopts ZN28-12 series vacuum circuit breaker, equipped with CDI7 series electromagnetic operating mechanism or CT19 series spring operating mechanism, and the isolating switch adopts GN30-12 rotary isolating switch or GN22-12 high current isolating switch series. product.
Model and its meaning
![]()
①Box type switch equipment
②Fixed
③Indoor installation
④Design serial number
⑤Rated voltage 12KV
①Indoor installation
⑥Type of circuit breaker: S-less oil (or no note); Z-vacuum; F-six gasification sulfur
⑦Operation form: (T: spring operation D: electromagnetic operation)
⑧Rated thermal current A
⑨Rated thermal stability current KA
Conditions of Use
•Ambient temperature upper limit +40°C; lower limit -5°C;
• The altitude does not exceed 1000m;
• The daily average value of relative humidity is not more than 95%, and the monthly average value is not more than 90%;
• The earthquake intensity does not exceed 8 degrees;
• There is no fire, explosion hazard, serious pollution, chemical corrosion and severe vibration.
• If the above environmental conditions are exceeded, the user should consult with the manufacturer.
Technical Parameters
Installation dimension drawing
![]()
Need to know when ordering
The user needs to provide the following information if ordering:• A wiring plan diagram and a wiring plan arrangement diagram.
• Secondary circuit schematic diagram, wiring diagram, terminal wiring diagram.
• List of primary and secondary equipment.
• The layout of the switch cabinet and the installation position of the busbar bridge.
• Please consult with our company for special conditions of use of spare parts and equipment.
high voltage switchgear components,lightning impulse withstand voltage