Red Color Switchgear Epoxy Resin Cast Bushing Heat Resistance 4000A 10kV

Place of Origin WENZHOU
Brand Name QIUPU
Certification ISO
Model Number CHN3-12Q/280 4000A
Minimum Order Quantity 60PCS
Packaging Details Cartons
Delivery Time 7 Days
Payment Terms T/T, Western Union
Supply Ability 50000PCS/Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Material Casting Resin Rate Voltage 12 KV
Frequency Voltage 42 KV Current 4000A
Creepage Distance 280mm Flexural Strength 8 KN
Color Red
High Light

epoxy resin cast insulators

,

cast resin insulator

,

Epoxy Resin Insulation Contact Box

Leave a Message
Product Description

CHN3-12Q/280 4000A 10kV Epoxy Resin Insulators Contactor Box Spolt Bushings

 

Gas, Steam, dust without seriously affecting the insulation of the contact box

 

No exploration or corrosive submission.


Technical Data & Requirements Requirement Technical data and requirements 1. Contact box and contact should be able to withstand frequency test voltage(effectiveness) 42 KV, 5 minutes, lightning shock(peak) 75 KV;

 

The label contact to earth call with power freedom test volume of 42 KV for 5 minutes and
Lightning impact vplage(peace value) of 75KV;

The temperature rise of the end of the contact box at the end of the line under long-term operation does not exceed 65 ℃ under the rated electricity;


The experience of lead-out final call not more than 65 °C if the contact box is used for long time in rate current con the wall-piercing sleeve is used to increase the insulation function of the mother-row in the cabinet and play a certain supporting role. In the middle, in the end.
Insulators only act as support, sometimes using a belt point sensor directly instead of an insulator as well as as as sensors.

 

The cabinet is large but easier to maintain. Medium case is large, but maintenance is more convenient. Ring case is small, but maintenance is not convenient.(Schneider SM6 now has a high voltage loop switch cabinet with special SFset circuit breaker. SGN1A-12(Z) small fixed separator, developed jointly, can achieve the basic function of medium case using ABB LEG(Z1)-12 circuit breaker, but the ring net case or small fixed compartment can be set up as a low voltage circuit breaker. Only according to the fixed mode of installation, so that when the circuit breaker failure, need to be replaced immediately, not only need to cut off the upper power supply, but also trouble to replace. It is convenient to replace the handcar switch.

 

Item Technical data
Rated voltage (KV) 3.6 7.2 12 24 40.5
Rated frequency(Hz) 50
Insulator(capacity) insulating Frequency withstand voltage 5 min (KV) 25 32 42 68 100
Frequency withstand voltage 1 min (V) 2000
Lighting impulse withstand voltage (KV) 40 60 75 125 185
Rated Current 4000A
Dispute bend (N) ≥10000
   

 

Red Color Switchgear Epoxy Resin Cast Bushing Heat Resistance 4000A 10kV 0